Schneider-ATV61HD45Y variable speed drive ATV61 - 45kW / 690V - 50HP / 575V - IP20

codice :  Schneider ATV61HD45Y
prezzo unitario :  10060.28 € (IVA inclusa)
 (Schneider)

EAN :  3389119214759

Schneider -
Main
Range of product
Altivar 61
Product or component type
Variable speed drive
Product specific application
Pumping and ventilation machine
Component name
ATV61
Motor power kW
45 kW 3 phases at 690 V
37 kW 3 phases at 500 V
Motor power hp
50 hp 3 phases at 575 V
Power supply voltage
500...690 V (- 15...10 %)
Supply number of phases
3 phases
Line current
62 A for 500 V 3 phases 37 kW / 50 hp
55 A for 690 V 3 phases 37 kW / 50 hp
51 A for 600 V 3 phases 37 kW / 50 hp
EMC filter
Level 3 EMC filter
Assembly style
With heat sink
Maximum prospective line Isc
22 kA 3 phases
Maximum transient current
70.8 A for 60 s 3 phases
Nominal switching frequency
2.5 kHz
Switching frequency
2.5...4.9 kHz with derating factor
2.5...4.9 kHz adjustable
Asynchronous motor control
Voltage/frequency ratio, 2 points
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Synchronous motor control profile
Vector control without sensor, standard
Communication port protocol
CANopen
Modbus
Type of polarization
No impedance for Modbus
Option card
Profibus DP V1 communication card
Profibus DP communication card
Multi-pump card
Modbus/Uni-Telway communication card
Modbus TCP communication card
Modbus Plus communication card
METASYS N2 communication card
LonWorks communication card
Interbus-S communication card
I/O extension card
Fipio communication card
Ethernet/IP communication card
DeviceNet communication card
Controller inside programmable card
CC-Link communication card
BACnet communication card
APOGEE FLN communication card
Complementary
Product destination
Asynchronous motors
Synchronous motors
Power supply voltage limits
425...759 V
Power supply frequency
50...60 Hz (- 5...5 %)
Power supply frequency limits
47.5...63 Hz
Continuous output current
59 A at 2.5 kHz, 500 V 3 phases
54 A at 2.5 kHz, 690 V 3 phases
52 A at 2.5 kHz, 575 V 3 phases
Speed drive output frequency
0.1...500 Hz
Speed range
1...100 in open-loop mode, without speed feedback
Speed accuracy
+/- 10 % of nominal slip for 0.2 Tn to Tn torque variation without speed feedback
Torque accuracy
+/- 15 % in open-loop mode, without speed feedback
Transient overtorque
130 % of nominal motor torque, +/- 10 % for 60 s
Braking torque
30 % without braking resistor
<= 125="125"
Regulation loop
Frequency PI regulator
Motor slip compensation
Adjustable
Automatic whatever the load
Can be suppressed
Not available in voltage/frequency ratio (2 or 5 points)
Diagnostic
1 LED red presence of drive voltage
Output voltage
<= supply="supply" power="power"
Electrical isolation
Between power and control terminals
Type of cable for mounting in an enclosure
Without mounting kit: 1-strand IEC cable at 45 °C, copper 90 °C XLPE/EPR
Without mounting kit: 1-strand IEC cable at 45 °C, copper 70 °C PVC
With UL Type 1 kit: 3-strand UL 508 cable at 40 °C, copper 75 °C PVC
With an IP21 or an IP31 kit: 3-strand IEC cable at 40 °C, copper 70 °C PVC
Electrical connection
L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB terminal 150 mm² / 300 kcmil
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR terminal 2.5 mm² / AWG 14
Tightening torque
L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB 41 N.m / 360 lb.in
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR 0.6 N.m
Supply
Internal supply 24 V DC (21...27 V), <= protection="protection" Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <= protection="protection" External supply 24 V DC (19...30 V), 30 W
Analogue input number
2
Analogue input type
AI2 software-configurable voltage 0...10 V DC, input voltage 24 V max, impedance 30000 Ohm, resolution 11 bits
AI2 software-configurable current 0...20 mA, impedance 242 Ohm, resolution 11 bits
AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolution 11 bits + sign
Sampling time
Discrete input LI6 (if configured as logic input)2 ms, +/- 0.5 ms
Discrete input LI1...LI5 2 ms, +/- 0.5 ms
Analog output AO1 2 ms, +/- 0.5 ms
Analog input Al2 2 ms, +/- 0.5 ms
Analog input AI1-/Al1+ 2 ms, +/- 0.5 ms
Absolute accuracy precision
AO1 +/- 1 % for a temperature variation 60 °C
AI2 +/- 0.6 % for a temperature variation 60 °C
AI1-/Al1+ +/- 0.6 % for a temperature variation 60 °C
Linearity error
AO1 +/- 0.2 %
AI2 +/- 0.15 % of maximum value
AI1-/Al1+ +/- 0.15 % of maximum value
Analogue output number
1
Analogue output type
AO1 software-configurable logic output 10 V, <= AO1 software-configurable voltage, analogue output range 0...10 V DC, impedance 470 Ohm, resolution 10 bits
AO1 software-configurable current, analogue output range 0...20 mA, impedance 500 Ohm, resolution 10 bits
Discrete output number
2
Discrete output type
(R2A, R2B) configurable relay logic NO, electrical durability 100000 cycles
(R1A, R1B, R1C) configurable relay logic NO/NC, electrical durability 100000 cycles
Maximum response time
R2A, R2B <= 0.5="0.5" R1A, R1B, R1C <= 0.5="0.5" <=
Minimum switching current
Configurable relay logic 3 mA at 24 V DC
Maximum switching current
R1, R2 on resistive load, 5 A at 30 V DC, cos phi = 1, L/R = 0 ms
R1, R2 on resistive load, 5 A at 250 V AC, cos phi = 1, L/R = 0 ms
R1, R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, L/R = 7 ms
R1, R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, L/R = 7 ms
Discrete input number
7
Discrete input type
(PWR) safety input, 24 V DC, voltage limits <= (LI6) switch-configurable PTC probe, 0...6, impedance 1500 Ohm
(LI6) switch-configurable, 24 V DC, voltage limits <= 3500="3500" (LI1...LI5) programmable, 24 V DC, voltage limits <= 3500="3500"
Discrete input logic
LI6 (if configured as logic input)positive logic (source), < 5 V (state 0), > 11 V (state 1)
LI6 (if configured as logic input)negative logic (sink), > 16 V (state 0), < 10 V (state 1)
LI1...LI5 positive logic (source), < 5 V (state 0), > 11 V (state 1)
LI1...LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 1)
Acceleration and deceleration ramps
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Braking to standstill
By DC injection
Protection type
Motor thermal protection
Motor power removal
Motor motor phase break
Drive thermal protection
Drive short-circuit between motor phases
Drive power removal
Drive overvoltages on the DC bus
Drive overheating protection
Drive overcurrent between output phases and earth
Drive line supply undervoltage
Drive line supply overvoltage
Drive input phase breaks
Drive break on the control circuit
Drive against input phase loss
Drive against exceeding limit speed
Insulation resistance
> 1 mOhm at 500 V DC for 1 minute to earth
Frequency resolution
Display unit 0.1 Hz
Analog input 0.024/50 Hz
Type of connector
Male SUB-D 9 on RJ45 for CANopen
1 RJ45 for Modbus on terminal
1 RJ45 for Modbus on front face
Physical interface
2-wire RS 485 for Modbus
Transmission frame
RTU for Modbus
Transmission rate
9600 bps, 19200 bps for Modbus on front face
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format
8 bits, odd even or no configurable parity for Modbus on terminal
8 bits, 1 stop, even parity for Modbus on front face
Number of addresses
1...247 for Modbus
1...127 for CANopen
Method of access
Slave for CANopen
Marking
CE
Operating position
Vertical +/- 10 degree
Product weight
68 kg
Width
320 mm
Height
630 mm
Depth
290 mm
Environment
Noise level
63.7 dB conforming to 86/188/EEC
Dielectric strength
5345 V DC between control and power terminals
3110 V DC between earth and power terminals
Electromagnetic compatibility
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
Conducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3
Standards
EN 55011 class A group 2
EN 61800-3 environments 1 category C3
EN 61800-3 environments 2 category C3
EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3-3 class 3C2
UL Type 1
Product certifications
CSA
C-Tick
DNV
GOST
NOM 117
UL
Pollution degree
3 conforming to UL 840
3 conforming to EN/IEC 61800-5-1
Degree of proctection
IP54 on lower part conforming to EN/IEC 61800-5-1
IP54 on lower part conforming to EN/IEC 60529
IP41 on upper part conforming to EN/IEC 61800-5-1
IP41 on upper part conforming to EN/IEC 60529
IP21 conforming to EN/IEC 61800-5-1
IP21 conforming to EN/IEC 60529
IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1
IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529
Vibration resistance
1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity
5...95 % without dripping water conforming to IEC 60068-2-3
5...95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation
50...60 °C with derating factor
-10...50 °C without derating
Ambient air temperature for storage
-25...70 °C
Operating altitude
1000...2260 m with current derating 1 % per 100 m
<=
Contractual warranty
Period
18 months


scheda tecnica

disponibile in giorni : 5

ordina il prodotto
Visualizza tutti i prodotti della categoria Drive standard
Visualizza tutte le offerte della marca Schneider
 
 Prodotti correlati

Schneider-ATV61E5D45N4 variable speed drive ATV61 - 45kW 60HP - 380...480V - EMC filter - IP54
Prezzo: 9805.92 euro   

Schneider-ATV61HD55M3X variable speed drive ATV61 - 55kW 75HP - 200...240V - IP20
Prezzo: 10142.45 euro   

Schneider-ATV61HD55N4 variable speed drive ATV61 - 55kW 75HP - 380...480V - IP20
Prezzo: 9270.26 euro   

Schneider-ATV61HD75N4 variable speed drive ATV61 - 75kW 100HP - 380...480V - IP20
Prezzo: 10480.14 euro   

Schneider-ATV61HD75N4Z variable speed drive ATV61 - 75kW 100HP - 380...480V - IP20
Prezzo: 10256.57 euro   

Schneider-ATV61WD45N4 variable speed drive ATV61 - 45kW 60HP - 380...480V - EMC filter - IP54
Prezzo: 9520.62 euro